Impeller-type rotating siren for large-area emergency warning. Available in 9 models from 500 metres to 16 km coverage. Supplied with motor starter, tested, and ready to install.
| Model Code | Coverage | Motor | Supply | Output |
|---|---|---|---|---|
| PC-MS-1S-050 | 500 m | 0.05 HP | 230V AC, single phase | 112 dB |
| PC-MS-1S-100 | 1 km | 0.1 HP | 230V AC, single phase | 116 dB |
| PC-MS-1D-200 | 2 km | 0.25 HP | 230V AC, single phase | 118 dB |
| PC-MS-1D-325 | 3.25 km | 0.5 HP | 230V AC, single phase | 120 dB |
| PC-MS-3D-500 ★ | 5 km | 3 HP | 415V AC, three phase | 122 dB |
| PC-MS-3D-800 | 8 km | 5 HP | 415V AC, three phase | 124 dB |
| PC-MS-3D-1150 | 11.5 km | 7.5 HP | 415V AC, three phase | 125 dB |
| PC-MS-3D-1600 | 16 km | 10 HP | 415V AC, three phase | 126 dB |
| PC-CBS-1D-500 | 5 km | 2 HP | 220V AC, single phase (CBS) | 122 dB |
★ PC-MS-3D-500 is our top-selling model — most Indian factories in the 1–20 acre range select this.
Table visible on desktop. WhatsApp us for full model specs on mobile.
Electronic sirens lose audibility rapidly beyond 300–500 metres in high ambient noise environments. Motor-driven rotating sirens produce a wailing tone that cuts through industrial noise and can be heard across multi-kilometre distances. For OISD-117 and ERDMP compliance, motor sirens are specified for main plant alerting.
The coverage range stated in our specifications is the diametrical range in still air — a theoretical maximum under ideal conditions. On the ground, actual audible range depends on several factors:
Practical example — 0.5 km model:
We recommend selecting the model with 1.5× to 2× your required coverage distance. Most sites with 2 km diagonal select the 5 km model (PC-MS-3D-500).
Models up to PC-MS-1D-325 (3.25 km) run on 230V single phase — standard factory power available at most distribution boards. Models from PC-MS-3D-500 (5 km) upward require 415V three phase, as the larger motors need three-phase power for starting torque and continuous running.
If your site only has single phase available at the siren location, the maximum model is PC-MS-1D-325. For larger coverage, a three-phase supply needs to be extended to the siren mounting point.
Yes. The motor siren requires a dry contact or relay input to start and stop. This can be provided by:
Yes — the motor siren is supplied with a matching DOL (direct-on-line) starter panel. For three phase models, a star-delta starter is supplied where required. The starter is pre-wired to the siren motor and includes overload protection.
Tell us your coverage distance, ambient noise level, and power supply. We confirm the model within one working day.